2015年7月14日星期二

Mute oil free air compressor maintenance

  Whatever types of air compressor ,the need for routine maintenance, but different types, type compressor, machine maintenance way and also has certain differences, should be carried out according to the characteristics of the compressor itself to maintain, mute oil free compressor, for example, when doing routine maintenance, nine attention, attention should be paid to the following by DENAIR, head of the air compressor maintenance for everyone to do detailed introduction.

  1. in strict accordance with the air pressure on the calibration of the rated voltage, frequency, load of work, the effect will be better, more secure;

  2. mute oil free compressor itself does not contain any oily substances, avoid by all means is to add any lubricating oil and oily substance;

  3. pay attention to the power supply voltage is in conformity with air compressor brand logo. Power supply voltage is higher than the voltage applied to the air compressor, may cause personal injury and damage, air compressor, power supply voltage is lower than the air compressor applied voltage, will cause a bad start, even damage the motor;

  4. when not in use from work, get into the habit of timely cut off power supply. Mobile air compressor or other equipment connection, must cut off power supply;

  5. should be cleaned in time according to the use of filter, regular check accessories, cables, damage the replaced immediately. Should keep the machine clean dry non-stick oil, so as to give full play to its performance. Air compressor when not in use, should put off the air in the store jar, drainage of sewage in the store jar, stored in a dry environment;

  6. must according to the manufacturer at set pressure range operation (general factory set the maximum pressure as 8 Bar, safety pressure relief 8.8 Bar), otherwise there will be a gas tank explosion danger;

  7. regularly inspect and replace inlet filter appropriately, general operation 300 hours after an inspection, the user check frequency according to the condition of use to decide on their own. Keep the filters and muffler clean can avoid most of the fault, don't clean the filter can reduce the performance of the compressor and the service life of the compressor;

  8. timely drainage of sewage in the store jar, suggested that emissions should be at least once a week.

  9. the correct use of the environment: air compressor normal use environment in 5 ℃, 40 ℃, shall not be placed in a place without shade not working in the damp and dark place, rigorous in store flammable and explosive liquid gas and dust, volatile place to work. Maintain a clean and tidy environment, and avoid unnecessary accidents.

没有评论: